Automatic installations for verification of electricity meters

The unit is designed to adjust and verify three-phase and single-phase active, reactive or active and reactive 0.2S accuracy class energy meters when measuring active energy and accuracy class 0,5S when measuring reactive energy and less accurate. Verification of meters can be carried out both in automatic and manual modes.

FEATURES:

The following operations can be performed on the stand:

-   ����������,

-   starting current test,

-   test without load (self-propelled),

-   error check (accuracy class),

-   accounting correction check,

-   testing influencing quantities (reverse phase,

     voltage imbalance, harmonic   waves, etc.) imbalance,

-   measurement stability check.

PWM (pulse width modulator) is used to amplify the voltage and current at the output of the stand, which provides high efficiency (efficiency is > 85%) and reduces heating. PWM has functions of fault checking, presetting, warning and protection.

Measurement generator uses the latest digital technology to control sine harmonic waves of frequency, amplitude and phase control. Measurement generator can increase several times (from 2-21 times) the primary harmonic of a sinusoidal wave and cause subharmonic waves, including excess subharmonic waves.

The stand uses a processor system for determining the meter error, to which the meter is connected via the RS485 communication method.

It is possible to simultaneously test meters with different constants (counter constant) of identical modification at the stand.

Scanning (measuring) heads with 3-spectrum range adjustment can be mounted on the test bench. Stand can receive signals both from meters with disk-based measurement, and from meters with digital LED pulse measurement.

The test bench has an automatic black mark detection search function that can detect it without load and start tests.

For automatic testing of various meters, the test bench uses a test program combined with WINDOWS98/2000/XP/7 operating systems.

No

Parameter

Unit

Parameter value

1

Current regulation range

A

3×(0,001ナ120)

2

voltage regulation range

(Unom =3�220 V)

V

3×(1ナ300)

3

Output power, per phase:

In current circuit

In current circuit

V��

1500

800

4

Non-sinusoidality of current and voltage signals at maximum load, no more than

%

0,5

5

Phase control range

Phase angle setting accuracy

degrees

0ナ360

ᄆ0,1

6

Frequency control range

Frequency setting accuracy

Hz

45-65

0,01

7

Defined harmonics

2ナ21

8

Installation error:

-current

-voltage

%

ᄆ 0,5

ᄆ 0,5

9

Instability of set values for 120 s of:

-current

-voltage

-ᅠpower

%

ᄆ 0,05

ᄆ 0,05

ᄆ 0,05

10

THD at maximum

load:  - by voltage circuits (from 0.8 to 1.15 Unom)

                    - by current circuits (from 0.05 Inom to Imax)

 

%

%

no more than ᄆ 0,5

no more than ᄆ 0,5

11

Maximum output power:

by voltage circuits

along the current circuit

V��

3×800

3×1500

12

HS-9503B current transformer accuracy class

for cosφ = 0.5C-1-0.5L, in the current range 3x(0.1ナ120) A, no more than

%

0,01

13

Output power of current transformers

V��

60

14

Limits of permissible relative error of the reference meter HY-5303C, in the ranges of

���������                              3×(40�480)V

�����                                           3×(0,01�120)A

when measuring active energy, no more than

when measuring reactive energy, no more than

%

Accuracy class

0,05

0,1

ᄆ 0,05

ᄆ 0,1

ᄆ 0,1

ᄆ 0,2

15

Number of simultaneously checked meters

pcs.

1ナ16

16

Operating temperature range

º�

20 ᄆ 5

17

Supply voltage

V

3×220/240 ᄆ 15%

18

Mains frequency

Hz

50 or 60

19

Power consumption, no more than

V∙�

3×3000

20

Stand dimensions (length; width; height)

mm

2200; 600; 1920

21

Chamber dimensions (length; width; height)